Figure template · System & Network · 4:3
Layered Regional IES with Electricity, Heat and Hydrogen Flows
A three-layer architecture for a regional integrated energy system: physical assets linked by colour-coded electricity, heat and hydrogen lines, an operational dispatch chain, and a green-certificate market. It frames modelling papers and energy grant proposals.
Prompt
Create a scientific figure about: Layered regional IES with electricity, heat, and hydrogen flows. Visual style: Clean Vector. Requirements: publication-ready scientific quality, clear labels and directional arrows where appropriate, avoid cartoon or stock-photo look, composition optimized for research papers and academic slides.
What this template is
The top platform holds the physical system: wind turbines and solar PV feed battery storage and the grid, an electrolyser sends hydrogen to storage tanks and on to industry and buildings, and heat storage links to district heating by red lines. The middle platform chains forecasting, optimization and unit commitment, energy and heat dispatch, storage management, demand response and grid operations with dashed information arrows. The bottom platform runs from renewable producers through certificate issuance, a trading platform and buyers to retirement and compliance. Readers should see how multi-energy flows are coordinated physically, operationally and through a market at once.
Elements to label
Physical infrastructure layer
The top platform; swap the sample wind turbines and PV for the generation mix of your own region.
Wind turbines and solar PV
Generation assets at the left of the top platform, wired by black lines; add installed capacity or an output profile if relevant.
Electrolyser and hydrogen storage
Blue lines run to the H2 tanks and on to industry; state whether a fuel cell returns hydrogen to power.
Heat storage and district heating
Red lines join the tank and heating station; note whether heat comes from boilers, heat pumps or electrolyser waste heat.
Operational dispatch layer
Six linked steps on dashed information arrows; relabel them with day-ahead or intraday time scales.
Green-certificate trading layer
Issuance through to retirement on green dashed certificate arrows; a price signal can be added to the chain.
Inter-layer arrows
Vertical arrows join the physical and dispatch layers; say whether they carry measurements or control commands.
Legends
One legend sits top right and another at the bottom with the same entries; keep only one of them.
Where it is used
- Paper mechanism figure
- Grant proposal
- Defense slides
- Academic poster
What reviewers look for
Energy versus information
Red heat arrows pass from the physical platform into the dispatch layer. Reviewers will point out that dispatch handles data and commands, so only information should cross between layers, never physical energy flows.
Hydrogen back to power
Hydrogen lines enter the grid substation with no fuel cell or hydrogen turbine in between. Expect a request to add the conversion unit and to give its efficiency in the model description. Otherwise the hydrogen loop stays open.
Certificates in the optimization
A single line links the certificate layer to dispatch. Reviewers will ask how certificate prices or quotas enter your model, whether as revenue in the objective function or as a constraint. Draw that link explicitly.
Boundary and time scale
The regional boundary, the dispatch time resolution and any exchange with the upstream grid are not shown. Modelling papers usually state all three in the figure itself or in its caption. Readers need them to judge the results.
How to use it in Yila
- 1Pick a figure
- 2Describe your subject and the steps to stress
- 3Refine it in chat, then download the PNG
Tips
Do
- List your assets and the direction of each energy flow so the three line colours follow your real topology.
- Ask for a fuel cell or hydrogen turbine on the hydrogen branch to close the hydrogen-to-power path.
- Have the dispatch steps carry time scales such as day-ahead scheduling and real-time adjustment.
Avoid
- Keeping heat and hydrogen arrows that cross between layers; inter-layer links should be signals only.
- Leaving both duplicate legends in place, which crowds the layout and invites inconsistencies after edits.
- Adding every device in your model to the top platform; group small units so the icons stay readable.
Questions
Can I use this energy system figure directly in my paper?
It works as a base for a framework figure, but it is AI-generated, and the device links and flow directions are not taken from your topology. Check every arrow, delete the duplicate legend and explain each layer in the caption before submitting. A co-author who built the model should confirm the flows.
Can I add or remove devices, or change a layer?
Devices and text boxes cannot be moved one by one, and the PNG is not a vector graphic. Describe the change in a Yila chat, such as adding a gas turbine, removing the certificate layer or replacing certificates with carbon trading, and the figure is regenerated in the same style.
Which format will I get?
An AI-generated PNG with the three platforms stacked in a landscape layout. If you need precisely aligned text, consistent fonts across figures or a vector submission, redraw the layout in illustration software and use the PNG as the blueprint. Keep the three platforms in the same order.
Is the template free?
Viewing this page and the sample image costs nothing. Generating and editing in Yila consumes credits, and new users receive 2,500 credits at sign-up, enough to compare a few layouts before settling on one for your paper. Opening sample pages like this one never uses credits.
My model uses carbon trading, not green certificates. Can the bottom layer change?
Yes. Name the market mechanism and its participants, for example allowance allocation, trading and compliance, and Yila redraws the bottom layer accordingly. The dispatch layer can gain a carbon-cost step at the same time so the two layers stay consistent. Rename the trading platform to match your market.
Can electric vehicles or cooling loads be added?
Yes. Add charging stations, chillers or cooling demand to your asset list and say which energy flow each one connects to, and Yila places matching icons on the physical layer. If you add a cooling flow, ask for a fourth line colour and a matching legend entry.





