High-Field NMR Spectrometer Setup

A vertical cutaway of a high-field NMR spectrometer: the nested superconducting magnet with a cryoprobe in its bore on the left, and the console with its RF, gradient and preamplifier lines at the lower right.

Updated Oct 16, 2026Reviewed by Roxy Liu7.93K854

Prompt

Create a scientific figure about: High-field NMR spectrometer: superconducting magnet (vacuum jacket, liquid nitrogen and liquid helium dewars, superconducting coils, shim coils, room-temperature bore), cryoprobe and pneumatic sample changer, and the NMR console (transmitter, receiver, ADC, pulse programmer) with its signal paths. Visual style: Clean Vector. Requirements: publication-ready scientific quality, clear labels and directional arrows where appropriate, avoid cartoon or stock-photo look, composition optimized for research papers and academic slides.

What this template is

The figure opens a superconducting magnet from the outside in. A vacuum jacket encloses a liquid nitrogen dewar, which encloses a liquid helium dewar, and the superconducting coils sit in the helium, producing a static field B0 along the Z axis. Shim coils occupy the upper bore. A pneumatic sample changer drops the tube into the room-temperature bore, where it lands in a cryogenically cooled triple-resonance probe inserted from below. Preamplifiers pass the probe signal to the console, where the receiver and ADC digitise it under a pulse programmer. A reader should leave knowing where field, RF and data travel.

Elements to label

  • Vacuum jacket and nitrogen dewar

    The two outermost concentric shells, each leader line ending on its own wall rather than inside the helium.

  • Liquid helium dewar

    One pale blue volume with the temperature printed once inside it, and the coils fully immersed.

  • Superconducting coils

    Two symmetric coil blocks flanking the bore; spell the caption in full on one line.

  • Shim coils

    A horizontal coil stack in the upper bore, named by the gradient orders it corrects, such as Z1/Z2.

  • Room-temperature bore

    Bracket the central channel with arrows and note the vacuum separating it from the cold space.

  • Cryoprobe

    Inserted from below with its tip at field centre, labelled with its nuclei and whether it carries a gradient coil.

  • Pneumatic sample changer

    Mounted on top, with a curved arrow and a tube tracing the sample's drop to the probe.

  • NMR console

    Separate boxes for transmitter, receiver, ADC and pulse programmer, with arrows that follow the real signal direction.

Where it is used

  • Paper mechanism figure
  • Course handout
  • Defense slides
  • Lab website

What reviewers look for

  • RF and gradient lines run backwards

    The sample's RF arrow points from the probe into the transmitter, and a gradient line feeds the receiver. Pulses leave the transmitter for the probe, and gradients come from their own amplifier. Redraw both before review.

  • The cryoprobe appears twice

    A probe insert already sits in the bore, yet the inset labelled CryoProbe shows a sample spinner and air bearing, and its dashed circle lands on a magnet coil. Settle on one drawing.

  • Typos and cropped captions

    The coil caption reads "Supercondo-ducting", the field direction note ends in a meaningless letter code, and both the magnet label at the bottom and the storage caption at the right are cut off.

  • Where the persistent switch belongs

    The persistent mode switch is a short superconducting section of the coil circuit, so its leader should not point at the main winding. Move the label and its note to the crossed box if that is what it shows.

How to use it in Yila

  1. 1Pick a figure
  2. 2Describe your subject and the steps to stress
  3. 3Refine it in chat, then download the PNG

Tips

Do

  • Put your own field strength, probe model and observed nuclei in the prompt so the labels match your instrument.
  • For teaching, colour the RF, gradient and preamplifier lines differently so students can follow each to its end.
  • When the talk is about the magnet, shrink the console to one box and give the space to the dewar layers.
  • Ask for the B0 arrow and the Z axis to be drawn once, since the sample repeats the field arrow on the left.

Avoid

  • Do not let the sample tube line pass into the cold space; in the sample it reaches inside the helium region.
  • Do not stack several parameter lines inside the helium volume, where they cover the coil outline and field arrow.

Questions

Can this go straight into a paper?

Treat it as a draft instrument schematic. Before submission, correct the RF and gradient directions, reconcile the two cryoprobe drawings, fix the misspelled and cropped captions, then keep refining it in chat until type size and resolution meet your journal's rules.

Can I change the parts shown?

Not element by element, but you can keep refining it by chatting in Yila: drop the sample changer, expand the console into a finer block diagram, swap in a magic-angle spinning probe for solids, or keep only the magnet cutaway. Ask for one change per message so you can compare versions.

What format is delivered?

An AI-generated PNG, with the magnet filling most of the frame and the console at the lower right. It is not a vector graphic, so preview it at column width and check that small captions like the shim and preamplifier labels stay legible. If they blur, ask for fewer captions.

Is it free?

Viewing this page and the sample costs nothing. Generating your own version in Yila consumes credits, and a new account receives 2,500 credits, enough for several rounds of matching the magnet, probe and console to your own instrument.

We run a benchtop low-field system. Does it adapt?

Yes. Benchtop instruments usually use a permanent magnet with no cryogens, so ask for both dewars to be removed and the superconducting coils replaced by a permanent magnet, keeping the probe and console much as they are. State your field strength so the magnet label matches.

Can I keep only the magnet cutaway?

Ask for the vacuum jacket, both dewars, the coils and the shims alone, enlarged to fill the frame. It suits a slide on why a superconducting magnet needs layered insulation, with the console left for the next slide. Larger dewar labels help in a lecture hall.