Figure template · Lab Apparatus · 4:3
Exploded Wearable Patch on a Mouse for Sensing and Drug Release
A device overview: a mouse wears a flexible patch that is pulled apart into an exploded layer stack, while three lower panels explain temperature sensing, pH sensing and voltage-triggered drug release. It suits soft-electronics and closed-loop dosing papers.
Prompt
Create a scientific figure about: Exploded wearable patch on a mouse with sensing and drug release. Visual style: Clean Vector. Requirements: publication-ready scientific quality, clear labels and directional arrows where appropriate, avoid cartoon or stock-photo look, composition optimized for research papers and academic slides.
What this template is
At upper left a white mouse carries a green flexible patch with a chip and a round component on its back, and a dashed line leads to an exploded stack: a clear encapsulation sheet with a round element, a sensor array of gold components, a substrate with traces, a position labelled tiny battery, and a pinned wireless chip. Three panels below show a thermistor with a falling resistance–temperature curve, two electrodes with a beaker inset for pH, and a reservoir of orange drug particles with a close-up of release through a polymer. Readers should see how one patch monitors physiology and doses on demand.
Elements to label
Mouse with patch
The patch sits on the mouse's back between the shoulders; note the attachment method and how long it is worn.
Encapsulation
The clear top sheet carrying a round component; name the encapsulant and any breathing holes in it.
Sensor array
The circuit layer of gold components; list the sensor types and their positions in the label.
Tiny battery
Its leader points to the substrate edge with no battery drawn; mark the real position of the cell when you revise.
Wireless chip
The pinned square chip at the bottom of the stack; write the link used, such as Bluetooth or near-field communication.
Thermistor panel
Resistance falls as temperature rises in the inset curve; label it as a negative temperature coefficient element.
pH panel
Two electrodes and a beaker inset; relabel them as working and reference electrodes mounted on the patch.
Drug-release reservoir
A well of orange particles with a close-up of drug leaving the polymer; name the drug and the polymer.
Where it is used
- Paper mechanism figure
- Graphical abstract
- Defense slides
- Grant proposal
What reviewers look for
Layer order and skin side
The sensor array sits under the encapsulation and above the substrate, far from the skin. Reviewers will ask how the sensing face touches the skin and why the drug reservoir is missing from the stack.
pH sensing principle
The pH inset shows protons travelling between electrodes in a beaker, which does not match potentiometric pH sensing. Show a working electrode whose potential shifts with pH, measured against a reference electrode.
Power source
The tiny battery leader points at the substrate edge and no cell is visible. Reviewers will look for the power strategy, the operating time between charges, and whether the device weight suits a mouse.
Release control
Voltage-triggered release needs the polymer's response mechanism, the trigger threshold and the release kinetics. Reviewers will also ask whether sensor readings actually drive dosing in a closed loop or only run alongside it.
How to use it in Yila
- 1Pick a figure
- 2Describe your subject and the steps to stress
- 3Refine it in chat, then download the PNG
Tips
Do
- Give the real layer order and say which layer faces the skin, so the exploded view matches your device.
- Ask for the drug reservoir to appear in the stack, linked by an arrow to its close-up panel below.
- Replace the beaker in the pH panel with working and reference electrodes drawn on the patch itself.
Avoid
- Keeping a battery leader that points at nothing; reviewers who cannot find the cell will doubt the whole drawing.
- Drawing the patch oversized relative to the mouse, which invites questions about animal welfare.
- Labelling every gold component in the sensor array; name the sensor groups and leave detail to the caption.
Questions
Can I put this mouse patch figure straight into a paper?
Use it as a draft device overview. It is AI-generated, so the layer order, circuitry and electrodes are not drawn from your design files. Check the stack and sensing principles, fix the battery leader and mark the figure as schematic in its caption before submission.
Can I edit one layer or one sensor?
Layers cannot be selected and edited individually, and the image is not a vector graphic. Describe the change in a Yila chat, for example adding a glucose sensor or replacing the battery with a wireless power coil, and the whole figure is regenerated around it. The other panels keep their style.
What format is the download?
An AI-generated PNG in landscape: mouse and exploded stack above, three function panels below. If a journal needs vector files, redraw the layout in illustration software from this reference, keeping the dashed link between the mouse and the stack.
Is there any cost?
Opening this page and viewing the sample costs nothing. Generating and each revision in Yila consume credits, and newly registered accounts receive 2,500 credits, enough to try a few layer orders and colour schemes. Viewing samples never uses credits.
My patch goes on a rat or a human arm. Can the subject change?
Yes. State the wearer and the body site, such as a rat's back or a human forearm, and Yila redraws the subject at a suitable patch scale. The function panels can follow your own list of sensors and actuators. Keep the exploded stack unchanged.
Can I show data streaming to a phone?
Yes. Ask for a signal arrow from the wireless chip to a phone or receiver with a simple live trace on its screen. If your paper is about closed-loop dosing, have the receiver send a command back to trigger the release panel. A phone icon is enough; avoid screenshots.




