Seven-Step Experimental Workflow, Sample to Interpretation

A seven-panel workflow that uses a genomic DNA sequencing run to make each generic stage concrete, from sample preparation and reagent steps through readout, quality checks and data interpretation, for methods papers, grant technical routes and teaching handouts.

Updated Oct 16, 2026Reviewed by Roxy Liu7.68K1.2K

Prompt

Create a scientific figure about: Experimental workflow from sample preparation, assay execution, readout, quality control, and interpretation. Visual style: Clean Vector. Requirements: publication-ready scientific quality, clear labels and directional arrows where appropriate, avoid cartoon or stock-photo look, composition optimized for research papers and academic slides.

What this template is

The sample turns a generic experimental workflow into one short-read sequencing run. Cells are lysed, high-molecular-weight DNA is extracted and sheared by sonication, and end repair, A-tailing and adapter ligation build the library; bead size selection and PCR enrich it; bridge amplification forms clusters on a flow cell; sequencing by synthesis reads fluorescent signal cycle by cycle; images become base calls and read files; and alignment, variant calling and annotation lead to interpretation. A reader should see where the quality checks sit between steps, and which stage turns physical molecules into data that software can read.

Elements to label

  • Sample preparation

    Lysis, DNA extraction and sonication on one row, with the fragment size trace labelled so its x axis reads as fragment length.

  • Reagent steps

    Give end repair, A-tailing and adapter ligation one arrow each, and name the two adapter ends at the fork.

  • Size selection checkpoint

    Keep the bead selection and the post-PCR library size trace together as the quality gate before loading.

  • Assay execution

    Lay out surface primers, bridge folding and amplification cycles in order, ending at labelled clonal clusters.

  • Signal readout

    Show reversible terminators, laser excitation and imaging per cycle, making clear that one base is read in each cycle.

  • Data processing

    Images become base calls and read files; the sample's text in this panel is garbled and needs rewriting.

  • Interpretation

    Chain alignment, variant calling, the variant file and annotation, and say where the conclusion goes at the end.

Where it is used

  • Grant proposal
  • Course handout
  • Paper mechanism figure
  • Defense slides

What reviewers look for

  • Aligners are not the reference

    The sample writes aligner names in brackets under the reference genome, mixing an input with a tool. Label the reference sequence on its own and leave software names to the legend or methods, so the figure stays correct when the tool changes.

  • The read file text is garbled

    The lines meant to show read format in panel six are misspelled words, which tells a reviewer nobody checked the figure. Replace them with a note on the standard four-line layout or show only a file icon.

  • Checkpoints should be measurable

    The fragment and library size traces are the real quality gates here. Any target size range written on the figure must match the shearing settings and selection ratios reported in your methods, or the figure and the text will disagree.

  • Instruments as generic shapes

    The sample prints instrument brands and models in several places and labels the cluster station as a library. Replace these with function names such as sequencer, thermal cycler and fragment analyzer, and keep one consistent shape per instrument type.

How to use it in Yila

  1. 1Pick a figure
  2. 2Describe your subject and the steps to stress
  3. 3Refine it in chat, then download the PNG

Tips

Do

  • If your assay is not sequencing, name it in the prompt, such as an immunoassay or mass spectrometry, so the panels switch reagents and readout.
  • To stress quality control, ask it to enlarge the two size traces and mark each checkpoint in the same colour.
  • For a grant technical route, ask for one line of expected output under each panel so reviewers see what every step delivers.

Avoid

  • Do not keep the instrument brands and software names from the sample; function names travel better through peer review.
  • Do not read the fluorescence bars in panel five as data; they only sketch the per-cycle readout.
  • Do not let the interpretation panel end on a file icon alone; state the biological question the variants answer so the pipeline has a destination.

Questions

Can it go straight into a paper?

Use it as a draft of your technical route or methods schematic. It is an AI-generated PNG, and the sample carries garbled text, instrument brands and software written where the reference should be, so check every panel and keep refining it in chat until it meets the journal's rules.

Can I change elements in the figure?

Not element by element, but you can keep refining it by chatting in Yila: swap sonication for enzymatic fragmentation, drop PCR for a PCR-free library, or change the last panel to expression quantification, then generate a new version and compare it with the previous one before choosing.

What format is delivered?

An AI-generated PNG image laid out as seven landscape panels, ready for a proposal or slide. It is not a vector graphic, so if you plan to enlarge it across a page, first confirm that the small labels in each panel stay readable.

Is it free?

Opening this page and viewing the sample cost nothing. Generating in Yila consumes credits, and new accounts get 2,500 credits, enough to rebuild this pipeline around your own assay over several rounds of edits, including versions sized for slides and for a proposal page.

My experiment is not sequencing. Does it still fit?

Yes. The seven panels follow sample, reagents, assay, readout, quality control, processing and interpretation, which suits most assays. Describe your method and readout in the prompt and it will replace each panel's content while keeping the order, so the quality checkpoints still sit between preparation and readout.

Can I keep only the bench steps?

Yes. Ask it to drop the base calling and bioinformatics panels, enlarge the first five into two rows, and end with a note on what is handed over for sequencing, which suits a practical class that covers library preparation only.

Download sample PNG